Introducing our top-of-the-line Hydraulic Magnetic Circuit Breaker, designed to provide optimal circuit protection for your electrical needs. This product boasts a cutting-edge technology that guarantees efficient and reliable performance.

Our Hydraulic Magnetic Circuit Breaker is engineered to safeguard your electrical systems from overloads, short circuits, and other electrical faults. It is built with premium materials that ensure durability and longevity, making it a cost-effective investment for your business.

With its sleek and modern design, our Hydraulic Magnetic Circuit Breaker is easy to install and operate. It is also equipped with advanced safety features that prevent accidental tripping and other hazards.

Invest in our Hydraulic Magnetic Circuit Breaker today and experience the peace of mind that comes with knowing your electrical systems are protected by the best in the industry. Trust us to provide you with the highest quality products and unparalleled customer service.

状态:
数量:
  • CVP-FR

  • Chinehow

Number of Poles 1,2,3,4 poles 

CURRENT
RATINGS

AC 0.1-32A(1,2,3&4 Poles)
DC 0.1-32A(1,2,3&4 Poles)

  

MAXIMUM
VOLTAGE

250V AC,277/480V AC,50/60Hz,
80V DC

VOLTAGE COIL 6V DC,12V DC;120V AC

AUXILIARY SWITCH
RATING

SPDT;7A,250V AC,7A(Res),28V DC,4A(Ind)0.25A-28V DC,0.1A-125V AC 
INSULATION RESISTANCE ≥100MΩ at 500V DC
DIELECTRIC STRENGTH 1500V,50/60Hz between terminals for eletrical 50/60Hz

RESISTANCE/
IMPEDANCE

The value between line and load terminal under ON status
ENDURANCE Mechanical life is 10k cycles(6 times operation per min.)and electrical life is 6k cycles at rated current and voltage
TRIP-FREE The circuit breaker will tripped inside even if the handle forcibly held in the ON position when overload
TRIP INDICETION Handle is in OFF position when overloaded.For mid-trip,handle is in middle position when overloaded
All CURVES Curve data shown represents breaker response at ambient temperature of 77°F (25°C) with no preloading. Breakers are mounted in standard wall-mount position. On 50 amp and less current ratings, the minimum inrush pulse tolerance handling capability is 12 times the rated current on standard delays and 25 times the rated current on high inrush delays. These values are based on a 60Hz 1/2 cycle, 8.33 ms pulse. High inrush delays should be for applications with high initial surge currents of short duration such as switching power supplies, highly capacitive loads and transformer loads.
TEMPERATURE OPERATION -40℃ to +85℃
RECOMMENDED TORQUE #6-32 or M3 mounting inserts 0.8-1.0 Nm; #8-32 or M4 screw terminals 1.4-1.7 Nm; #10-32 or M5 screw terminals 1.7-2.3 Nm; #1/4-20 or M6 screw terminals 3.4-4.0 Nm
MAXIMUM POLES 4 Poles
TERMINALS upturning,screw-in,bus screw-in 
ACTUATOR long handle,Short handle
COLOR OF CASE black
STANDARD EN60934,UL1077,GB17701,UL489A